Survitec Completes Testing of New Firefighting Foams

Survitec has successfully completed extensive performance testing of new alcohol-resistant fluorine-free firefighting foam concentrates.

The results validate the compatibility of the new foam concentrates with marine foam mixing systems and demonstrate that a safe transition away from PFAS (Per- and PolyFluoroAlkyl Substances) based products is not only feasible and ready for operational deployment across a range of vessel types, but also technically proven.

The latest performance tests are a continuation of extensive due diligence work by Survitec on the new fluorine-free formulae. Last year, Survitec’s fire safety specialists conducted laboratory fire tests to assess performance in accordance with maritime rules and regulations using various types of foam sprinkler nozzles on different burning media across different setups.  The results confirmed that the foam remained stable and performed well, even against challenging fuels such as methanol.

However, in the case of alcohol-resistant, fluorine-free foam concentrates, there was an additional challenge to address: viscosity. These new formulations rely on different active ingredients to maintain firefighting effectiveness without using fluorinated compounds. The result is a denser, more viscous fluid that behaves differently under varying flow conditions, posing new challenges for marine dosing systems originally designed for lower-viscosity foams.

“Standard proportioners are not typically designed to handle this kind of fluid, so it was essential that we rigorously test the system to ensure compatibility and dosing accuracy,” explained Maciej Niescioruk, Product Manager, Foam Systems, at Survitec.

Rather than replacing existing proportioning systems, Survitec focused on engineering modifications to internal components and orifices. The outcome of the tests was clear; the extent of system modifications varied depending on the type and size of the system, with certain configurations requiring more substantial redesign than others to maintain accurate dosing within the required range.

As Niescioruk explains, “An incorrect dosing ratio can result in a foam that is ineffective in suppressing a fire. Foam proportioning systems must comply with a strict dosing accuracy range of    -0% to +30% to ensure that underdosing does not occur – a critical requirement to avoid system failure.

“This is particularly important when using high-viscosity foam concentrates, which typically generate higher flow resistance. If a standard, unchanged, proportioner is used, the increased resistance can cause the actual mixing ratio to fall below the nominal value, violating regulatory requirements and compromising foam performance. By implementing our findings from these tests, we can ensure that our customers won’t face that risk.”

In addition to proportioner compatibility, appropriate pump selection is essential. A standard centrifugal pump designed for low-viscosity, Newtonian fluids, such as the fluoroprotein alcohol-resistant foam concentrates, will most likely fail with the new, fluorine-free formulae, which exhibit non-Newtonian, pseudoplastic behaviour. The worst case scenario is a total system malfunction, where no foam is produced.

The tests come at a crucial time for the industry. From January 1, 2026, the IMO’s MSC.532(107) regulation will prohibit the use and storage of foams containing PerFluoroOctane Sulfonate (PFOS). This chemical is part of the wider PFAS family now being phased out globally due to growing concerns over its impact on human health and the environment. However, some manufacturers have already discontinued production of PFAS foam concentrates in anticipation of further restrictions. Consequently, for shipowners and operators, managing the transition to fluorine-free alternatives is not only a compliance issue but a safety-critical one.

“Fluorine-free, alcohol-resistant foams are particularly suited for chemical tankers, Norwegian double-ended ferries, and methanol-fuelled vessels, where environmental performance and fire safety are paramount. The successful completion of these performance tests allows Survitec to offer a tested and validated solution that mitigates technical risk and supports a smooth, compliant transition to fluorine-free technology. The findings are already being implemented in current projects, including a system commissioning in Turkey,” added Niescioruk.

As additional PFAS restrictions loom and more countries advocate for a total ban on fluorinated foam concentrates, the results of Survitec’s testing offer reassurance that regulatory compliance does not need to come at the expense of safety or operational readiness. However, planning and the support of an OEM are essential to avoid costly mistakes.

“These are safety-critical systems,” warns Niescioruk. Any significant changes to these systems must be handled carefully, allowing time to assess the engineering requirements and obtain the proper approvals. Our message to the market is clear: plan now, test early, and work with an OEM partner who understands the technical and regulatory landscape.”

Survitec’s S Word podcast explores the complexities of transitioning to fluorine-free firefighting foams. From unpacking new regulations, comparing foam performance and safety, and outlining key considerations for retrofitting.

To read more news and articles see our latest issue here.

Never miss a story… Follow us on:
LinkedIn: International Fire Buyer
Twitter (X): @Firebuyer
YouTube: @FireBuyerTV

Media Contact
Rebecca Spayne, Managing Editor, International Fire Buyer
Tel: +44 (0) 1622 823 920

About Fire Buyer

International Fire Buyer is the leading authority in global passive and active fire content, delivering expert news, in-depth articles, exclusive interviews, and industry insights across print, digital, and event platforms. Published 10 times a year, the magazine is a trusted resource for professionals seeking updates and analysis on the latest developments in the fire sector.

To submit an article, or for sponsorship opportunities, please contact our team below.

Chris Lingham image - Fire Buyer

Chris Lingham

Group Sales Manager

Afua Akoto picture - Fire Buyer

Afua Akoto

Marketing Manager

Read the Latest Issue

Follow us on X

Follow us on X

Click Here

Follow us on LinkedIn

Follow us on LinkedIn

Click Here

Advertise here

Reach decision makers and amplify your marketing

Advertise here

Click Here

Related News

Picture of ROCKWOOL factiry - Photo by ROCKWOOL - Fire Buyer

ROCKWOOL Invests in Global Fire-Stopping Hub

Insulation manufacturer ROCKWOOL has launched a new global centre of excellence for fire-stopping at Hams Hall, on the outskirts of
Picture of firefighter wearing non-PFAS turnout gear - Photo by FIre-Dex - FIre Buyer

East Providence Firefighters Receive Non-PFAS Turnout Gear

The East Providence Fire Department has become the first in the United States to purchase and use non-PFAS turnout gear department-wide
Picture of forest fires - Photo by ECA - Fire Buyer

Press Briefing Reports on EU funding to tackle Forest Fires

The European Court of Auditors (ECA) is to host an online press briefing on its upcoming special report on how EU money is used to tackle
Picture of Ben Pfahl - Photo by Fire-Dex - Fire Buyer

Fire-Dex Appoints New Chief Information Officer

Fire-Dex has announced the appointment of Ben Pfahl as its Chief Information Officer (CIO), putting weight behind its promise to lead with

Product Spotlight – FFE

Early, reliable fire detection is critical to protecting people, assets, and infrastructure in demanding settings – an evolving challenge

From the Expert – Stat-X

Ultrasense from Fireaway, a new generation of fire protection combines early anomaly detection and advanced aerosol suppression to

Feature Sponsor – IWMA

As fire safety technologies evolve, how do water mist systems compare to traditional sprinklers? New UK data sheds light on performance
Magazine - ask the expert - Bridging Standards

Ask the Expert – Sensitron

Marco Penso, R&D Manager at Sensitron, explores the evolving regulatory landscape, innovation challenges, and sustainability efforts shaping

Ask the Expert – F&G Detection

Eliot Sizeland, Vice President of Business Development at Fire & Gas Detection Technologies Inc., discusses the challenges of flame

Cover Story – Perimeter Solutions

Solberg Spartan offers safer, faster fire suppression—Kurt Becker of Perimeter Solutions explains how this foam is redefining frontline
Scroll to Top