ARFF Vehicle image - Fire Buyer

RIV-601/F IR Flame Detector

Model number: RIV-601/F Make: Control Logic S.r.l.. Weblink: http://www.controllogic.it Specification Attachment: Teaser: IR flame detector model watertight enclosure The IR flame detector model RIV-601/F is an electronic optical fire detector device that responds immediately to the thermal infrared radiation emitted by fire, and is tuned to the pulse frequency of the flame to ignore sun, lamps and other light and infrared radiation sources. WHY IR (infrared) FLAME DETECTOR Eye is faster than nose. In the event of live fire the IR flame detector responds immediately. Its behaviour is similar to that of the eye. In fact it "sees" the radiation emitted by fire, and its sensitivity is inside a cone of 90° which is called the field of view. The minimum flame size that can be detected by the RIV-601/F varies with the distance. It doubles at double distance and is half at half distance. The sensitivity value is 2-3% of the distance. For example, at 10 m the smallest detectable flame size is 20-30 cm.   Cast aluminium watertight case, IP 66 grade protection (dust and water spray). Explosion-proof available with the model RIV-601/FA. Power voltage 24VDC +/-15% (20 to 28 V). Current consumption 13 mA in stand-by (0.25W), 50 mA in alarm state (max 1.5W including 20 mA for test). Anti-inversion diode on +24V and + Test (T+). Spectral response infrared 1 to 3 micron. Tuned to flame pulsing frequency (flickering) of 5 to 20 Hz. Field of view 90° cone. The detector can see outside the field of view or indirectly by reflection, or even through smoke, with a reduced sensitivity. Sensitivity 2-3% of the distance, which means that the smallest detectable flame size is 2-3% of the distance. For example, at 10 m the smallest flame size is 20 cm. Typical covering figure is 400 square meters at 20 m distance. Alarm delay time set to 5 sec. Adjustable from 1 to 10 sec. Reset is automatic. The detector turns on 5 seconds after the flame is started. As soon as the flame stops, the detector returns off. Front LED lamp lights in alarm. It blinks shortly during the teletest. Output on changeover SPDT relay contact rated 1A 30VDC. Other output on NPN transistor open collector rated 50mA 24VDC, which goes low in alarm. Built-in "Teletest" device for the remote monitoring of the detector ability. Needs a 24VDC +/-15% 20mA.Built-in modulator. When the teletest circuit is powered, a small incandescent bulb placed near the sensor starts pulsing so as to simulate a flame. During the test the detector turns on for half a second every 4 seconds. The teletest can be remotely controlled from the control panel, or can be wired for a continuous and automatic operation. Control panel must recognise the short test pulses from the alarm state, which is steady on. Electrical wiring on 8 way terminal block. Operating temperature -20 +60 °C. Storage temperature -40 +85 °C. Cable entry fitting PG21 (hole diameter 29mm). Dimensions 180 x 92 x 80 (H) mm (mounting holes 118 x 76 mm). Weight 800 grams. Manufactured in compliance with the essential requirements of the directives 73/23/EEC + 93/68/EEC (Low voltage) and 89/336/EEC + 93/68/EEC (EMC) and in compliance with EN 60065 safety standards. EN 54-10 class 2 approved, VdS Approval Certificate no. G 205044  

RIV-601/F IR Flame Detector Read More »

Firefighting foam being sprayed from fire hose - Fire Buyer

FirstCheck+

Model number: FirstCheck+ Make: Ion Science Ltd. Weblink: http://www.ionscience.com Specification Attachment: Teaser: FirstCheck+ Multi-Gas PID Detector FirstCheck+ is the first multigas to combine complete VOC and toxic gas detection from ppb up to 10,000 ppm with traditional multigas sensors for oxygen (O), hydrogen sulphide (H2S), carbon monoxide (CO) and explosive gas (LEL) detection – providing a must have instrument for first responders and confined space entrants. The instrument’s unique, highly sensitive photoionisation detector (PID) enables the detection of many gases that are toxic at low ppb levels and are undetectable by other multigas instruments. Traditionally two to three instruments are needed to ensure workers safety now FirstCheck+ has it all covered in one handheld detector. FirstCheck+ offers a rapid response enabling speedy assessment of a given situation or incident allowing the appropriate response to be initiated swiftly and smoothly. FirstCheck+ Features: * ppb – 10,000 ppm for unrivalled multigas detection of VOC’s and toxic gases * Large numerical back-lit display for easy viewing of readings in adverse conditions * Real time graph display for an instant assessment of readings * Data download via infrared port to a PC for analysis of all 5 sensors output with easy to use software * Health and Safety mode for STEL and TWA monitoring * Display all 5 readings in a graphical or numerical format for simultaneous assessment * Icon driven menu for easy of understanding and to eliminate translation difficulties * Intrinsically safe for use in flammable areas  

FirstCheck+ Read More »

Fire fighter in the outfit, with fire protection mask - Fire Buyer

Evolution EVC-DP

Model number: Evolution EVC-DP Make: Nittan Weblink: http://www.nittan.co.uk Specification Attachment: Teaser: Evolution EVC-DP Conventional Dual Photo-electric Detector Technical summary The Evolution Dual Photoelectric smoke detectors EV-DP and EVC-DP both use a new, unique Dual LED optical chamber, which utilises both Blue and Infra-Red LED’s to effectively measure the size of particles in the chamber. This methodology is based on Gustav Mie’s particle scattering Theory (published 1908), and has enabled Nittan group to design cost effective Optical smoke detectors with a number of enhancements over standard Single Optic smoke detectors and Optical-Heat Multi-sensors. Measurement of the particle size enables the smoke detector to discriminate between combustion particles and much larger particles (Steam, Dust etc) which are a major cause of False Alarms in Automatic Fire Detection systems. In the event that Steam or Dust is present, the decision to Initiate a Fire Alarm condition can be inhibited or delayed. Single sensor Optical smoke detectors (and even Multi-sensors) cannot make this decision, since they can only decide if the amount of scattered light striking the Photo-diode is greater than the Alarm threshold. Single sensor Optical smoke detectors are basically sensitive to large and gray combustion particles generated by TF2 (Smoldering wood fire) and by TF3 (Smoldering cotton fire) and less sensitive to small combustion particles generated by TF1 (Open wood fire) and black particles by TF5 (Liquid (N-heptane) fire). However, using the Dual Photo technique (and compensating algorithms), this lack of sensitivity can be reduced – again since the particle size is effectively being measured. In the presence of small or black combustion particles, the signal can be amplified (multiplied) to take it over the Alarm Threshold. DP detectors can therefore replace Ionisation detectors, which ARE sensitive to small particles. The DP detectors are still optical devices however, so they will remain insensitive to the invisible aerosols that Ionisation detectors respond quickly to (causing False Alarms). Whilst DP detectors will give a reduction of False Alarm signals in the event of Transient Steam or Dust, which would set off Standard Optical detectors, they are generally not suited to being placed in Dirty or Dusty environments. Other detectors are available which can be safely situated in these environments.  

Evolution EVC-DP Read More »

Image of Wildfire - Fire Buyer

Fenzy Aeris Confort

Model number: Fenzy Aeris Confort Make: Sperian Respiratory Protection France. Weblink: http://www.sperianprotection.com Specification Attachment: Teaser: NZY Aéris range covers all the requirements of Self Contained Compressed Air Breathing Apparatus users. Modular and adaptable, the FENZY Aéris range covers all the requirements of Self Contained Compressed Air Breathing Apparatus users.  The FENZY Aéris Confort various models accept four different kinds of masks, two different demand valves and a full range of accessories as the FENZY Angel 1 Personal Distress Signal Unit and the FENZY Angel 2 Warning and Monitoring Device with its telemetric systems. Fully safe, the FENZY Aéris Confort is also extremely convenient and gives welfare at work. Features: • Moulded anatomic and self-extinguishing back pack • 3 carrying handles & 3 attachment points on the harness for life line with pulling resistance up to 150Kg. • Harness with Nomex® backing cushions on shoulder and belt straps to ensure perfect comfort during use and ideal weight distribution. • Flame retarded shoulder straps and belt with fast adjustment buckle. • 2 reflective straps on front side of the shoulder strap cushion. • Rapid shoulder strap and twin belt adjustment system. • Easy and quick adjustable cam lock device to secure any type of cylinder strap tightening. • Easy connection for all types of cylinders in one-cylinder or two-cylinder configurations. • HP/MP reducer with high-reliability compensated piston, equipped in series with two MP outlets. • High power acoustic alarm > 90 db. CE 0194 (EN137-136) / ISO 9001 / VERITAS certified  

Fenzy Aeris Confort Read More »

Firefighting foam being sprayed from fire hose image - Fire Buyer

Dräger PSS® 3000

Model number: Dräger PSS® 3000 Make: Dräger Weblink: http://www.draeger.com Specification Attachment: Teaser: new generation of high performing breathing apparatus for firefighters. The Dräger PSS® 3000 is a new generation of high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance, it is designed for applications where simplicity and ease of use are key essentials. Lightweight yet robust, and easy to don, this advanced breathing apparatus provides the ultimate in breathing protection.

Dräger PSS® 3000 Read More »

Firefighting foam being sprayed from fire hose - Fire Buyer

Dräger PAS Micro

Model number: Dräger PAS Micro Make: Dräger Weblink: http://www.draeger.com Specification Attachment: Teaser: provides dual connectivity via a medium pressure line with integrated PSS® lung demand valves The Dräger PAS Micro – is designed as a short duration breathing apparatus (10, 15 and 20 minute) for Escape, Entry or Airline Escape use. An ergonomic design provides user comfort together with high resistance to friction and being impervious to water, chemicals and oils make it an ideal choice for various industrial applications. The PAS Micro provides dual connectivity via a medium pressure line with integrated PSS® lung demand valves (Escape units) or via a safety quick-connect coupling for the connection of all PSS® lung demand valves (Entry units)  

Dräger PAS Micro Read More »

Modern fire fighting truck in city - Fire Buyer

Dräger PAS Colt

Model number: Dräger PAS Colt Make: Dräger Weblink: http://www.draeger.com Specification Attachment: Teaser: designed as a short duration breathing apparatus (10, 15 and 20 minute) The Dräger PAS Colt – – is designed as a short duration breathing apparatus (10, 15 and 20 minute) for Escape, Entry or Airline Escape use. An ergonomic design provides user comfort together with high resistance to friction and being impervious to water, chemicals and oils make it an ideal choice for various industrial applications. The sophisticated bandoleer style harness retains its form, with a releasable cylinder option available for use within confined spaces.

Dräger PAS Colt Read More »

Firefighting equipment image - Fire Buyer

Fenzy Opti-Pro

Model number: Fenzy Opti-Pro Make: Sperian Respiratory Protection France Weblink: http://www.sperianprotection.com Specification Attachment: Teaser: The FENZY Opti-Pro is part of the new generation of full face masks. It has a very modern design combining comfort and safety, suitable for every FENZY Self-Contained Breathing Apparatus and compatible with all models of FENZY demand valves. • Fully panoramic vision: guarantees an exceptional angle without optical deformation. • The face piece and inner half mask are made in high quality silicone offering optimal comfort and perfect tightness. • Three different sizes (S, M, L) to suit for all 100% shapes of faces. • Three different models for various applications: • With five point adjustable head straps • With Nomex® net • With fastening connection kit, ideal for fireman helmet • Equipped with high performance speech diaphragm compatible with communication kit. EN 136 : 1998 standard Certified to be used with FENZY SCBA certified EN 137 Manufactured under ISO 9001 Quality Insurance

Fenzy Opti-Pro Read More »

Firefighting foam being sprayed from fire hose image - Fire Buyer

MK2 RN/BN

Model number: MK2 RN/BN Make: Spasciani S.p.A. Weblink: http://www.spasciani.com Specification Attachment: Teaser: a self-contained compressed air B.A. The MK2 RN/BN is a self-contained compressed air B.A. to be used in case of oxygen deficiency or in highly contaminated environments. Owing to the versatily of use and easy operation it’s the basic equipment for fire-fighters and rescue team. Component Parts – The mask is a panoramic full facepiece connected to the demand valve by means a special quick connector. This mask can also be used in conjunction with gas canister with a standard EN 148-1 connector. – Demand valve: unique patented warning device inside of the demand valve. When the remaining pressure in the cylinder drops below a special device inside the demand valve actuates the acoustic warning. A loud vibration is made with every inhalation and terminates only when the air reserve is completely used up. The advantages of such a system are: • No air loss due to the warning whistle: longer duration • Closeness to the ear and repeat warning: best audibility • Warning device protected from frost and dirt deposition: function granted under all circumstance • Warning device working with extension hose even at a long distance from cylinders: granted audibility to the user – Compensated pressure reducer – Phosphorescent Gauge – Anatomically shaped back plate – Available with one steel cylinder 7 litres 200bar or 3 or 6 litres 300 bar or composite of various capacities.  

MK2 RN/BN Read More »

Firefighting foam being sprayed from fire hose image - Fire Buyer

TT Series

Model number: TT Series Make: IDE Compressors GmbH. Weblink: http://www.ide.de Specification Attachment: Teaser: Portable high pressure compressor unit for breathing air, air or other gases Portable high pressure compressor unit for breathing air, air or other gases. Preferred model row for the application on yachts, diving boats, small diving schools, on divingsafari vehicles and in fire-fighting vehicles at home and abroad Air delivery achievements of 100 litre/minute Motorizing (depending upon model) with 230 V, 400 V, Robin gasoline or Lombardini Diesel 200 bar or 300 bar (optionally 200 bar and 300 bar)

TT Series Read More »

Scroll to Top